INSTALLATION OPTION 1:
FUSION REMOTE CONTROL NETWORK
Connecting a FUSION Network
To avoid exceeding the power loading limitations of a FUSION remote control network the maximum number of
devices supported on a FUSION network is;
1. One FUSION Stereo Head Unit (MS-IP700i, MS-AV700i, MS-RA205, MS-BB300, MS-UD650, MS-AV650, MS-
UD750, MS-AV750).
2. Up to three MS-NRX200i remote controls.
For installations requiring a greater number of devices or connecting to other NMEA 2000 equipment the
installation of a full NMEA 2000 network is required. Refer to Option 2.
Connecting the MS-NRX200i to a FUSION Stereo
For the MS-IP700i, MS-AV700i, MS-RA205 and MS-BB300 stereos use the red Powered Drop Cable supplied
with the stereo.
For the MS-UD650, MS-AV650, MS-UD750 and MS-AV750 stereos the WIRED REMOTE cable is located in the
wiring loom at the rear of the stereo.
Important Note: To provide power to the remote controls on the FUSION remote control network ensure NRX
POWER is enabled in the setting menu. Press the ‘Menu’ button and select ‘SETTINGS’ > ‘NRX POWER’ select
ON (MS-UD650, MS-AV650, MS-UD750 and MS-AV750 only).
NMEA 2000
TEE-CONNECTOR
NMEA 2000
BACKBONE CABLE - 6M
NMEA 2000
INLINE TERMINATOR
NMEA 2000
FEMALE TERMINATOR
FUSION Stereo Powered Network
Powered Drop Cable
Supplied with Stereo
FUSION
STEREO